Product Presentation  

Product Features



1.Bioresorbable scaffold with minimum profile diameter 
The scaffold is compatible with 4 ~ 6F sheath and is applicable to fine infant blood vessels of newborn. 
2.High post-expansion limit 
The post-expansion limit at the time of implantation is  nominal diameter +1mm.
3.Secondary intervention expansion 
The breakpoint design of multiple through-holes is preset on the struts of the scaffold to ensure the circumferential deconstruction as soon as possible after 6 months, which is conducive to secondary intervention expansion when necessary, and does not restrict the short-term growth of blood vessels. 
4.Reasonable degradation profile
Effective support for 6 months and complete degradation in about 2 years, without restricting long-term growth of blood vessels.
Product Features


         1.Thinnest  

          The world's thinnest scaffold with 70 μm , the world's only iron-based bioresorbable  technology path.            2.Longest 

          The breakthrough 118mm length, can cover the lesion length up to 200mm by overlapping use which 

         can meet the real world clinical application needs.                    

         3.Excellent operation performance   

          The scaffold is compatible with 5F catheter and has excellent visibility. The nominal diameter of the post 

         expansion limit is +0.75mm.      

          4.High drug utilization 

          The content of sirolimus is 1.4μg/mm2, with most of the drug being located on abluminal surface of the 

         struts.     

         5.Reasonable degradation profile 

          Effective support for 6 months and fully degradable in about 1.5 years, allowing secondary intervention 

         expansion when necessary.

IBS Sirolimus-Eluting Iron Bioresorbable Coronary Scaffold System
IBS Sirolimus-Eluting Iron Bioresorbable Coronary Scaffold System

Product Features



1.World's thinnest   

70 micron total thickness, the world's only iron-based bioresorbable technology path.      

2.Excellent operation performance    

           The scaffold is compatible with 5F catheter. The nominal diameter of post-expansion limit is  +0.75mm.   
          3.Good visibility     
         Two sets of gold radiopaque markers are located at both ends of scaffold to enhance the visibility.       
          4.Rapid endothelialization  
Animal experiments show faster than mainstream permanent stents
          5.Reasonable degradation profile    
           Effective support for 6 months and  complete degradation in about 1.5 years.
IBS Angel™ Iron Bioresorbable Scaffold system
IBS Angel™ Iron Bioresorbable Scaffold system
IBS Titan™ Sirolimus-Eluting Iron Bioresorbable Peripheral Scaffold
IBS Titan™ Sirolimus-Eluting Iron Bioresorbable Peripheral Scaffold
Product Presentation